Operating Manual
© Dürr Systems AG
100 / 156
EcoBell2 SL EC - Rotating Atomizer with External Charging
Cleaning and maintenance
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
There is a thread cleaner that considerably facilitates this cleaning
work. The Thread cleaner is discussed in the chaoter on
“Accessories”.
• Activate the shaft detent.
• To clean the thread, carefully turn the thread cleaner in the thread
of the hollow shaft to its stop.
Fig. 50: Thread cleaner in the thread of the hollow shaft
• Remove the thread cleaner again from the shaft.
If necessary, repeat the process several times.
• Remove the residue loosened by the thread cleaner from the
hollow shaft.
Bell disk and shaft end must be undamaged.
Loosen the knurled screw on the special tool so that the clamp of the
special tool can be opened up.
Fig. 51: Bell disk with tool
• Place the bell disk into the open tool.
The bell disk must sit with its edge in the solid half shell.
• Close the clamp carefully.
Only when the bell disk is in the correct position can the clamp be
closed with minimal effort.
• Tighten the knurled screw with light manual force.