Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Cleaning and maintenance
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
101 / 156
A T T E N T I O N
Risk of damage to property and production disruption
Thread of the bell disk can be damaged.
First, screw the bell disk onto the shaft by hand, without a torque
wrench. Just apply manual force.
Screw the bell disk onto the shaft only if it can be done easily.
If the bell disk is screwed improperly onto the shaft end of the turbine,
the threads of bell disk and turbine may be damaged. An improperly
mounted bell disk leads to irreparable damage to the turbine.
• Set the bell disk on the shaft end manually and turn the bell disk a
few times on the thread.
• For final tightening, set the torque wrench on the special tool.
Fig. 52: Mounting the bell disk
A T T E N T I O N
Risk of damage to property and production disruption
Not maintaining the given torque will inevitably cause damage to bell
disk and turbine.
Moreover, malfunction must be expected during operation.
Watch the torque when screwing on the bell disk.
• Screw the bell disk tight onto the shaft with a torque of 6 Nm.
• Remove the torque wrench from the bell disk using the special tool.
• Release the shaft detent.