Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Cleaning and maintenance
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
99 / 156
A T T E N T I O N
Danger from tilted distributor disk
This could result in damage to the distributor disk.
Pay attention while assembling the distributor disk and make sure that
the distributor disk is not tilted while pressing it into the housing.
If the distributor disk does not engage in the housing, the distributor
disk must be disassembled again.
• Inspect the retaining ring of the distributor disk and replace it, if
necessary.
• Turn the bell disk by 90° and press it on the assembly tool again.
A T T E N T I O N
Danger from tilted distributor disk
This could lead to production disruptions.
At the time of assembly, make sure that the distributor disk is correctly
seated in the housing.
An incorrectly assembled distributor disk will cause disruptions in
operation:
- The paint is not evenly spread
- The bell disk gets dirty sooner
- The bell disk cannot be easily cleaned.
7.5.1.3
Screwing the bell disk onto the shaft
The assembly of the bell disk follows the reverse sequence of the
disassembly.
• First, make sure that the thread and cone of the bell disk and of the
shaft end are absolutely clean. Paint residue must also not be
present.
W A R N I N G
Danger from bell disk
Soiling of the thread can impede the proper mounting of the bell disk.
The bell disk may detach from the shaft.
Completely remove all soiling.