13. Use the up/down arrow buttons to review
the results of the test. The screen shows the
following information for each transponder:
• Frequency
of the transponder signal
• Power
of the transponder signal (in
dBm—power ratio in decibels of the
measured power referenced to one
milliwatt)
• Measurement of the signal-to-noise ratio,
expressed as
SNR
in decibels
•
Measurement of the signal quality, expressed as an
SQ
value between 0 and 100
• Frequency
offset
of the transponder signal from its expected frequency (in
megahertz)
• Indication whether the transponder signal is above the power
lock
threshold
• Voltage
supplied (in volts)
• Current
supplied (in milliamps)
• ODU
used
• SWiM
channel used
14.
Troubleshoot any problems following the instructions provided by DIRECTV. To repeat
the test at a different location, press
CHANGE LOC
15. Press DONE to return to the
TEST
screen.
Use PAGE UP and PAGE DN to scroll quickly through test
results. Press the left/right arrow buttons to navigate through
the columns.
Summary of Contents for Advanced Installation Meter 2
Page 6: ...Page 6 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 12: ...Page 12 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 14: ...Page 14 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 44: ...Page 44 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 50: ...Page 50 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 60: ...Page 60 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 66: ...Page 66 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 92: ...Page 92 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 104: ...Page 104 AIM 2 Operation Manual THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 108: ...Made in U S A ...