Product information
Products: safety technology
SafeLine
redaction 11 date 10.04.09 page 5 from 48
Safety regulations
•
The unit may only be installed and operated by those who are qualified electrical engineers or have received sufficient
training and are familiar with both these instructions and the current regulations for safety at work and accident prevention.
Follow VDE, EN as well as local regulations especially as regards preventative measures!
•
Ignoring the safety regulations can lead to death, serious injury or cause considerable damage!
•
In emergency stop applications use the internal function “Speed output restart disable” or a higher level control unit must
ensure that the machine cannot start up again automatically!
•
Transport, storage and operating conditions should all conform to
EN 60068-2-1, 2-2
. See technical details
•
Any guarantee is void following unauthorised modifications. This can lead to death, serious injury or cause considerable
damage!
•
The unit should be cabinet mounted, otherwise dampness or dust could lead to functional impairment.
•
Adequate fuse protection must be provided on all output contacts especially with capacitive and
inductive loads.
•
The unit must be installed following the specification of
DIN EN 50274, VDE 0660-514
regarding the required distances.
•
During operation, parts of the electronic switchgear carry high voltage.
•
DANGER! During operation the protective covers must not be removed from the electronic switchgear!
•
The device must always be replaced after the first malfunction!
•
The unit must be disposed of properly when it reaches the end of it service life.
•
Keep the operating instructions!
Intended usage
The
SAFELINE
series is a product with safety-relevant functions for machines and equipments.
With this product the most diverse functions at machinery can be supervised and/or steered.
Testing basis:
•
2006/95/EWG
„guidelines of low voltage usage"
•
2004/108/EG
„EMC-guidelines“,
A1, EN61000-6-2
EN 61496-1-2, VDE 0113-201 non contact protection device „BWS- interference immunity"
GS-ET-20: Principles for testing and certification of relay safety combinations"
DIN EN 62061 „Safety of machinery”, (VDE 0113-50)
DIN EN 61508-part3 „Principles for computers in safety systems “
The safety outputs correspond to DIN EN 62061, SIL CL 3, VDE 0113-50
As a motion monitor according to EN 60 204-1 /VDE 0113 part 1 corresponding to DIN EN 62061, SIL CL 3, VDE 0113-50.
As a standstill monitor according to EN 60 204-1/ VDE 0113 Part 1 corresponding to DIN EN 62061, SIL CL 3, VDE 0113-
50.
As logic unit for two-hand control function according to EN 574: Type III C (BG No.: ET 06146).
The analogue inputs (I16 to I20) are also used with a safety shutdown mat,
only
type TS/ W1 and TS/ BK1/ Fa. Mayser
The products are according to the requirements of the updated standards, which are listed in this document.