Product information
Products: safety technology
SafeLine
redaction 11 date 10.04.09 page 42 from 48
DNSL-RM technical data
Power consumption at at A1, A2 via the central module
Max 4,8W
Minimum current of contacts 11/12 to 83/84
10mA
Maximum current of contacts 11/12 and 81/82
DC13: 1A, 24V
Technical data of output contacts 13/14 to 83/84
according DIN EN 60947-4-1/ EN 60947-5-1
Switching capacity
DC13: 4A, 24V 0,1Hz
Electrical product life, DC13: 1A, 24V
100000 switching cycles
Electrical product life, DC13: 4A, 24V
40000 switching cycles
Mechanical product life
>10 x 10
6
switching cycles
Short-circuit strength
200A/automat B6, 800A/safety fuse 6Agl
Contact fusing
5A slow
Maximum switching cycles
360 cycles/h with max. current AC15, DC13
Typical reaction time, typical drop-out time
15ms
DNSL-RM 230 technical data
Power consumption at A1, A2 via the central module
Max 4,8W
Minimum switching current contacts 13/14 to 83/84
10mA
Switching capacity accord. DIN EN 60947-4-1/ EN 60947-5-1 AC15: 3A, 230V/ DC13: 4A, 24V
Electrical product life, DC13: 1A, 24V
100000 switching cycles
Electrical product life, AC15: 1A, 230V
200000 switching cycles
Electrical product life, DC13: 4A, 24V
40000 switching cycles
Electrical product life, AC15: 3A, 230V
80000 switching cycles
Mechanical product life
>10 x 10
6
switching cycles
Contact fusing
5A slow
Maximum switching cycles
360 cycles/h with max. current AC15, DC13
Short-circuit strength
1000A SCPD 6A gG safety fuse
Rated insulation voltage
250V AC
Impulse withstand voltage
4KV, pollution degree 2
Typical reaction time, Typical drop-out time
10ms
DNSL-KM
Power consumption at A1, A2 via the central module
Max 4,8W
Minimum switching current contacts 13/14 to 83/84
10mA
Switching capacity accord. DIN EN 60947-4-1/ EN 60947-5-1 AC15: 3A, 230V/ DC13: 4A, 24V
Electrical product life, DC13: 1A, 24V
100000 switching cycles
Electrical product life, AC15: 1A, 230V
200000 switching cycles
Electrical product life, DC13: 4A, 24V
40000 switching cycles
Electrical product life, AC15: 3A, 230V
80000 switching cycles
Mechanical product life
>10 x 10
6
switching cycles
Contact fusing
5A slow
Typical reaction time, Typical dropout time
10ms
Short-circuit strength
1000A SCPD 6A gG safety fuse
Maximum switching cycles
360 cycles/h with max. current AC15, DC13
Rated insulation voltage
250V AC
Impulse withstand voltage
4KV, pollution degree 2
Technical data of outputs O1 to O4
Switching and continuous current inductive and resistive load, Max. 0,25A, short and over load protected
Total switching and continuous current
Max. 0,4A
Typical reaction time
10ms