Product information
Products: safety technology
SafeLine
redaction 11 date 10.04.09 page 13 from 48
Central modules DNSL-ZMB, DNSL-ZMT
DNSL-ZMT
Schematic
14
V24
COM PORT
Netzteil
Power supply
24V DC
I1
I2
I3
I4
I5
I20
O1
O2
O3
13
23
24
A2
A1
0V
24V intern
6A
I19 I18 I17 I16 I15 I14 I13 I12 I11 I6
Eingänge / Inputs
Ausgänge / Outputs
UB = 24V DC
DNSL-ZMB and ZMT can be ordered with an integrated field bus, Profibus or Ether cat
module. Type with Profibus: DNSL-ZMB-DP, type with Ether cat: DNSL-ZMB-EC
DNSL-ZMB-DP
DNSL-ZMB, DNSL-ZMT: Inputs usage
Safety circuit 1 (SK1)
E1
⇒
I1
E2
⇒
I2
Q
⇒
I3 controls SK1
Safety circuit 2 (SK2)
E1
⇒
I4
E2
⇒
I5
Q
⇒
I6 controls SK2
Safety circuit 3 (SK3)
E1
⇒
I11
E2
⇒
I12
Q
⇒
I13 controls SK3
Only at ZMB
Safety circuit 4 (SK4)
E1
⇒
I15
E2
⇒
I16
Q
⇒
I17 controls SK4
Safety circuit 5 (SK5)
E1
⇒
I18
E2
⇒
I19
Q
⇒
I20 controls SK5
E1 and E2 may be used
in
static
or
clocked
mode.
E1
E2
Emergency Stop
E1
E2
E1
E2
Q
Quit
manually
automatic
Protection cover function.
E1
E2
11
12
21
22
E1
E2
Q
11
12
21
22
13
14
23
24
automatic
Permission function
Q
E2
E1
Quit
E2
E1
manually
automatic
Two-hand function
Q1 E1
Q2
E2
Only by
E1
⇒
I1
Q1
⇒
I2
E2
⇒
I3
Q2
⇒
I4
control ZH1
Static input signal only
According EN 574:
Type IIIC
Operation
mode Switch
(BAWS)
One from
three
24V
DC
BA/ Mode
1
2
3
I1 to I3
One from six
24V
DC
BA / Mode
2
3
4
5
6
1
I1 to I6
DNCO function
See page 27
or click here
DNSL-DS
Programming Layer
manually
automatic
Protection cover function
Two-hand function
Q
E1
E2
SK1-5
E1
E2
SK1-5
Q
E1
E2
SK1-5
Q2
E1
E2
ZH1
Q1
>500ms
Q2
OK
<500ms
The
static
/
clocked
and
manually
/
automatic
operation mode are defined in the parameter mask. In
manual
mode, restart is only possible using
Q
.
Note
: „
automatic
“ should be selected in the DESIGNER, if protection cover switch
with
quit contact is used. The
quit contact has to be connected to I3, I6, I13, I17 respectively I20.
“
automatic
“ should be selected in the DESIGNER, if there are safety circuits
without
quit contact. I3, I6, I13, I17
respectively I20 has to be connected to 24V DC.
All inputs may be used for optional functions.
SK1 to SK5 will be wired into the safety chain with the DESIGNER. The left side of the 1st contact must be con-
nected to
, the right side connects to the next contact.
SK1
SK2
+24V
. SK1 to SK5 and ZH1 are virtual redun-
dant contacts. Five
safety circuits
or
one
Two-hand function
and three
safety circuits
are possible.
These inputs may also be used as general-purpose inputs.