The direct path to safe automation
DIN EN 62061, SIL CL 3
Two-Hand-Control
according to EN 574: Type IIIC.
(BG-Nr: ET 06146)
IND.CONT.EQ
1 Z D 7
MTTF
D
: 25 years
DC
awg
:
≥
≥
≥
≥
99%
CCF according to EN 62061: 2005
85 points
CCF according to ISO 13849-1: 2006 95 points
PFH
D
= 6,24x10
-8
The total concept of the specified category must
be validated involving the whole control unit.
Variants management
FW
DESIGNER
V404.02x
V404.03x
V1.13
x
V1.20
Customer-specific
V1.31
x
V1.32
Customer-specific
V1.38
x
SafeLine DESIGNER Version 1.38B5
SafeLine modules
Central module DNSL-ZM
6 safe digital inputs
4 safe positive switching outputs
2 positive switching outputs, free configurable
1 positive switching output, system ready
V24 interface
Central module DNSL-ZMB
16 safe digital inputs
2 safe positive switching outputs
1 relay output with 2 safe contacts
1 positive switching output, system ready
V24 interface
Dual motion and standstill monitoring
Central module DNSL-ZMT
11 safe digital inputs
5 safe analogue inputs
2 safe positive switching outputs
1 relay output with 2 safe contacts
1 positive switching output, system ready
V24 interface
Dual motion and standstill monitoring
Central module DNSL-ZMR
16 safe digital inputs
4 safe positive switching outputs
2 positive switching outputs, free configurable
1 positive switching output, system ready
Control for the relay outputs module DNSL-KM
V24 interface
Dual motion and standstill monitoring
Central module DNSL-ZMK
6 safe digital inputs
2 safe positive switching outputs
1 relay output with 2 safe contacts
1 positive switching output, system ready
V24 interface
Central module DNSL-ZMA
6 safe digital inputs
1 analogue input
2 safe positive switching outputs
1 positive switching output, system ready
V24 interface
Function modules
Dual standstill, motion and direction monitor
module DNSL-DS, DNSL-DR
8 digital inputs
2 Encoder inputs
4 positive switching semiconductor outputs
DNSL-DR only outputs
Input module DNSL-IN
16 digital inputs
4 positive switching semiconductor outputs
Input / output module
8 digital inputs
10 positive switching semiconductor outputs
Relay module DNSL-RM, DNSL-RM 230
4 relay outputs
8 NO contacts
2 NC contacts only with DNSL-RM
Relay module DNSL-KM
4 safe relay outputs every with 2 safe NO contacts
4 signal contacts
Field busses
Profibus DP DNSL-DP
Interface, 24 byte input and output data,
for diagnostic purpose only
Ether CAT DNSL-EC
Interface, 24 byte input and output data,
for diagnostic purpose only
Summary of Contents for SafeLine DNSL-ZM
Page 1: ...SafeLine Product information Safety for men and machines...