Product information
Products: safety technology
SafeLine
redaction 11 date 10.04.09 page 36 from 48
The table below shows the ID Numbers of 14 spindles:
Position in the DNCO table
Spindle ID-number hexadecimal
slot at rack
Motion monitoring
48
0x21
2
1
49
0x22
2
2
50
0x31
3
1
51
0x32
3
2
52
0x41
4
1
53
0x42
4
2
54
0x51
5
1
55
0x52
5
2
56
0x61
6
1
57
0x62
6
2
58
0x71
7
1
59
0x72
7
2
60
0x81
8
1
61
0x82
8
2
62
0xF3
alle
alle
Spindle deactivation
1. Activate the function in the parameter mask of the field bus module.
2. At the DNCO1 select the wished spindle to be deactivated. This is accomplished as follows:
•
Push both buttons at DNCO1 simultaneously until „SP xx“ is flashing in the display of DNCO1. xx represents
the spindle-number 1 to 14. If all spindles have to be deactivated, “AL” has to be displayed.
•
Using the up and down buttons at DNCO1, the number of the requested spindle must be selected.
•
To deactivate, both buttons must be pushed simultaneously until the display is steady.
•
SafeLine is sending this information to the PLC using the field bus. The PLC must send an acknowledge within
2 seconds.
SafeLine sends the accordant ID-number of the selected spindle via the field bus to the PLC. The data will be
transferred via the input byte EB8. The PLC has to reconfirm the equal spindle ID-number during 2s via the output
byte AB8. If the ID-numbers are not equal, the spindle will be not deactivated.
Spindle activation
Using the DNCO1 select the deactivated spindle as acknowledge. See above!
Virtual wiring
Field bus is wired using the SafeLine DESIGNER.
The following sections describe the wiring between central module and field BUS for the input- and output data to
the field BUS MASTER.
Field BUS: Input-Data
Input-Data from Safeline to field bus Master are defined as 8 Bytes (EB1 – EB8). So 64 Diagnostic bits may be
send to field bus
Master.
Individual diagnostic bits will be assigned at the SafeLine DESIGNER wiring layer to the
Input data bits of the Master.
Wiring:
•
Left click on the
symbol will activate the wiring layer.
•
Left click on the selected module will show this module in the wiring layer.
•
Right clicking on a wire will show a selection window.
•
Positioning the mouse pointer at the
will show the input data bit list of field bus
Master „EB11 - EB88“.
•
A left click on one of the bits (Ex.
), will assign this bit to the wire. The bit is now representing
the status of this wire. The wire will become an additional symbol
indication the connection to field bus.
Example: Field BUS virtual wiring of input data bit to the field bus Master
Selection window
Indication