Product information
Products: safety technology
SafeLine
redaction 11 date 10.04.09 page 19 from 48
DNSL-KM Relay module
Connection scheme DNSL-KM
K4
K1
K2
K3
K4
O1
O2
O3
O4
Power
Info
K1 13 14 23 24 33 34 43 44
K3
54 63 64 73 74 83 84
Ausgangskontakte / Ouput contacts
K2
24VDC intern / internal
53
K5
K6
K7
K8
O1
O2
O3
O4
Output expansion for DNSL-ZMR with DNSL-KM:
The central module DNSL-ZMR can control directly a relay module of type
DNSL-KM
. This relay module provides 4
safety relay outputs each consisting of 2 safety contacts and 1 signaling contact. This module is placed in position
3 of the rack. If needed contact expansion is possible putting a second DNSL-KM at position 4 of the rack.
Four safety outputs each consisting of 4 safety contacts and 2 signaling contacts are available then.
Position 2 in the rack is reserved for the field bus module.
Parameter mask
DNSL-KM:
Field to label the output module
O1, O2, O3 and O4:
Fields to label the signaling contacts
R13 / R14, R23 / R24, R33 / R34, R43 / R44,
R53 / R54, R63 / R64, R73 / R74, R83 / R84:
Fields to label the redundant contacts.
OK: safe mask and loose.
Abbrechen: loose mask without safe.
Description of wiring layer
S1-S4
:
virtual inputs to control the 4 relay outputs
(Safety category 4)
O1-O4
:
Signaling relay contacts
13/14, 23/24
:
redundant contacts for the first relay output
33/34, 43/44
:
redundant contacts for the second relay output
53/54, 63/64
:
redundant contacts for the third relay output
73/74, 83/84
:
redundant contacts for the fourth relay output
+24V
virtual connection for 24V
Wiring layer
Summary of Contents for SafeLine DNSL-ZM
Page 1: ...SafeLine Product information Safety for men and machines...
Page 48: ......