Product information
Products: safety technology
SafeLine
redaction 11 date 10.04.09 page 16 from 48
Parameter mask DNSL-ZMT
Reset of safety mat
The reset of the virtual con-
tacts of the mat can be
automatically (AUTO).
The contacts close again, if
the mat is inactivated.
If (MAN) is selected, the re-
set has to be activated via
the virtual input RTDS.
RTDS can be controlled via
an software element or
hardware input.
Description of the parameter
mask: See page 8 and 9.
Note: Digital inputs and analogue safety mat inputs
will be processed in two channel mode and tested for plau-
sibility on the central – and all function modules. There is no single channel processing.
Malfunctions
Behavior
: Output O1 switched off. LED- for O1 not illuminated.
Left LED at
ZMB
block not on. Right LED at block blinking sequence short/long.
Correction
: Check the wiring
Check the configuration (wrong assembly of the rack or wrong project planning.)
Reset stored errors by switching 24V supply OFF and ON.
Memory of application
All application information will be stored on a pluggable „
Memory card
“ Type
DNSL-MC
. This card is plugged in-
ternally on the central module and is part of the central module DNSL-ZMB, ZMT and ZMR. It can also be ordered
separately.
Integration of the memory card on the
central module
The user application data can be transfer
to the memory card via the programming
device DNSL-PR.
Lock also at DNSL-ZMR for memory of
application.
DNSL-MC
DNSL-SP plugged
lower left part
on the
central module
Safety
Shutdown mat
low value
Safety
Shutdown mat
high value