Product information
Products: safety technology
SafeLine
redaction 11 date 10.04.09 page 29 from 48
DNSL-IN: Input module
DNSL-IN
Connection scheme
24V Intern
I11 I12 I13 I14 I15 I16 I17 I18
I21 I22 I23 I24 I25 I26 I27 I28
Power
Info
Info
24V Intern
O11 O12
O21 O22
Eingänge / Inputs
Eingänge / Inputs
Ausgänge
Outputs
Outputs
Ausgänge
Inputs usage
Safety circuit 1 (SK1)
E1
⇒
I11
E2
⇒
I12 and
Q
⇒
I13
control SK1S and SK1Ö
Safety circuit 2 (SK2)
E1
⇒
I15
E2
⇒
I16 and
Q
⇒
I17
control SK2S and SK2Ö
Safety circuit 3 (SK3)
E1
⇒
I21
E2
⇒
I22 and
Q
⇒
I23
control SK3S and SK3Ö
Safety circuit 4 (SK4)
E1
⇒
I25
E2
⇒
I26 and
Q
⇒
I27
control SK4S and SK4Ö
E1, E2 may be used in static or
clocked mode.
Clock signal:
E1
E2
All inputs may be used for
optional functions.
Emergency Stop
E1
E2
E1
E2
Q
Quit
manually automatic
Safety cover function
E1
E2
11
12
21
22
E1
E2
Q
11
12
21
22
13
14
23
24
automatic
Permission function
Q
E2
E1
Quit
E2
E1
manually automatic
Two-hand function
Q1 E1
Q2
E2
only by
E1
⇒
I11
Q1
⇒
I12
E2
⇒
I13 and
Q2
⇒
I14 control ZH1
Static input signal only
according EN 574:
Type IIIC
Programming Layer
manually
Q
E1
E2
SK1S-SK4S
SK1Ö-SK4Ö
automatic
E1
E2
SK1S-SK4S
SK1Ö-SK4Ö
Safety cover function
Q
E1
E2
SK1/ 2
Two-hand function
Q2
E1
E2
ZH1
Q1
>500ms
Q2
OK
<500ms
The
static
/
clocked
and
manually
/
automatic
operation mode are defined in the parameter mask. In
manual
mode, restart is only possible using
Q
.
Note
: „
automatic
“ should be selected in the DESIGNER, if protection cover switch
with
quit contact is used. The
quit contact has to be connected to I13, I7, I23 respectively I27.
“
automatic
“ should be selected in the DESIGNER, if there are safety circuits
without
quit contact. I13, I17, I23
respectively I27 has to be connected to 24V DC.
SK1 to SK5 will be wired into the safety chain with the DESIGNER. The left side of the 1st contact must be con-
nected to
, the right side connects to the next contact.
SK1
SK2
+24V
. SK1 to SK5 and ZH1 are virtual redun-
dant Contacts. Five
safety circuits
or
one
Two-hand function
and three
safety circuits
are possible.
The inputs may also be used as general-purpose inputs.