20
Operation
Resetting the counter
●
Resets the free counter and error counter.
1
Press
[
Menu
]
●
A [Cleaning] message appears.
2
Press
[
Next
]
to set to [Counter Reset]
3
Press
B
●
Resets the free counter and error counter.
Checking reset
●
Select [Free Cnt] or [Erorr Cnt] under [Counter setting].
Test print
●
Prints the printer’s built-in test pattern, or the different setting values.
●
When system troubles occur, printing can be performed using settings
on the printer or computer by operating only the printer.
Test types
●
Test Pattern:
Prints color patterns on a single side of a card.
●
Printer Setting:
Prints according to the values preset in the setting mode.
●
Network:
Prints according to the values preset through the network.
●
Lami Setting:
Prints according to the values preset in the laminator’s user
mode.
1
Press
[
Menu
]
●
A [Cleaning] message appears.
2
Press
[
Next
]
to display [Test Print]
3
Press [Change]
●
A [Test Pattern] message appears.
4
Press
A
and select a test type.
5
Press
B
●
Test print starts.
Contrast setting
●
This is used for setting the contrast of the operation panel display.
Setting values
-3, -2, -1, 0, 1, 2, 3
●
Selecting a larger value increases the contrast.
1
Press
[
Menu
]
●
A [Cleaning] message appears.
2
Press
[
Next
]
to set to [Setting]
●
Pressing the [Next] button each time displays the next screen.