PPC4™ OPERATION AND MAINTENANCE MANUAL
© 2009 DH Instruments, a Fluke Company
Page 140
IS
Increase the pressure slowly.
Ln
Gets or sets the command interpreter mode.
LAN
Read or set the optional network interface settings.
LL
Read or set the lower limit for the current range (negative gauge mode only).
LOCAL
Return control to the PPC4 front panel.
MEM
Read the power-up memory test status.
MMODE
Read or change the active measurement mode.
MODE
Read or set the current pressure control mode.
MSGFMT
Read or set the type of program message format to use.
NVENT
Read or set the status of the lo vent valve (Gxxx or BGxxx Q-RPT only).
PASSTHRU
Send a command string out of the PPC4 COM2 port.
PCAL:IH
Read or set the user Lo RPT calibration information.
PCAL:IL
Read or set the user Hi RPT calibration information.
PCALUNC:IH
PCALUNC:IL
Read or set the Q-RPT uncertainty settings used to determine the RPT’s measurement
uncertainty during operation.
PR
Read the next PPC4 pressure.
PRR
Read the next available pressure, rate, on-board barometer reading, control status, and
the QRPT uncertainty.
PS
Set a new target pressure and start automated pressure control.
PSF
Set a new target pressure and use only the fast speed to reach the target.
PSS
Set a new target pressure and use only the slow speed to reach the target.
QPRR
Quickly read the last known pressure, rate, on-board barometer reading, control status
and QRPT uncertainty.
RANGE
Read or set and Q-RPT or utility sensor default range (PPC4 command).
RATE
Read the next available rate of change of pressure.
READYCK
Read or set a flag that is cleared by a
Not Ready
condition.
REMOTE
Enable remote local lockout operation.
RES
Read or set the pressure display resolution for the current transducer and range.
RESET
Reset the PPC4 to the default user parameters.
RETURN
Start a new automated pressure control set using the current target value.
RPT
Read the available Q-RPT data or initiate the RPT search process.
SCRSAV
Read or set the front panel display screen saver activation time & type.
SN
Read the serial number of the PPC4.
SR
Read the next available pressure status (
Ready/Not Ready
).
SS
Read or set the stability required for a
Ready
condition.
SS%
Read or set the stability required for a
Ready
condition (% span/ s).
STAT
Read the pressure control status.
TIME
Read or set the current time of day.
TIMEFMT
Read or set the clock time format.
TP
Read the current target pressure.
UCOEF
Convert a pressure in Pascal to pressure in the current units.
UDU
Read or set the user defined pressure unit.
UL
Read or set the upper limit for the current range.
UNIT
Read or set the pressure unit of measure for the current range.
VAC
Read or set the exhaust reference status flag.
VENT
Read, execute or abort a vent process.
VER
Read the PPC4 software version.
ZOFFSETn
Read or set the AutoZero P
offset
for the specified Q-RPT.
ZOFFSET:IH
Read or set the AutoZ offset for Hi RPT.
ZOFFSET:IL
Read or set the AutoZ offset for Lo RPT.