4.1.12 Group 11 Advanced Parameters
Pr.
Explanation
Settings
Factory
Setting
VF
VFPG
SVC
FO
CPG
TQ
CPG
FO
CP
M
11-00 System Control
Bit 0=0: no function
Bit 0=1: ASR Auto tuning, PDFF enable
Bit 7=0: no function
Bit 7=1: When position control is enabled, it doesn’t need to set
Pr.07-02 (DC Brake Current Level)
Bit 15=0: when power is applied, it will detect the position of
magnetic pole again
Bit 15=1: when power is applied, it will start from the magnetic
pole position of previous power failure
0
○
○
11-01 Elevator Speed
0.10~4.00 m/s
1.00
○
○
11-02 Sheave Diameter
100~2000 mm
400
○
○
11-03 Mechanical Gear Ratio
1~100 1
○
○
11-04 Suspension Ratio
0: 1:1
1: 2:1
1
○
○
11-05 Inertial Ratio
1~300% 40
○
○
11-06 Zero-speed Bandwidth
0~40Hz 10
○
○
11-07 Low-speed Bandwidth
0~40Hz 10
○
○
11-08 High-speed Bandwidth
0~40Hz 10
○
○
11-09 PDFF Gain Value
0~200% 30
○
○
11-10
Gain for Speed Feed
Forward
0~500 0
○
○
11-11 Notch Filter Depth
0~20db 0
○
○
11-12 Notch Filter Frequency
0.00~200.00Hz 0.00
○
○
11-13
Low-pass Filter Time of
Keypad Display
0.001~65.535s 0.500
○ ○ ○ ○ ○
○
11-14 Motor Current at Accel.
50~200% 150
○
11-15 Elevator Acceleration
0.20~2.00m/s
2
0.75
○
11-16 Reserved
11-17 Reserved
11-18 Reserved