Chapter 3 Operation and Start Up
|
VFD-VL
3-4
3.3 Auto-tuning Operations
3.3.1 Flow Chart
IM
PM
Selection of s peed
feedback card
EMVL-PGABL
EMVL-PGABO
EMVL-PGH01
EMVL-PGS01
St ep 1 B asi c param et er sett i ng s
Source of the Master
Frequency C omm and
Pr. 00-14
Setting all parameters
to factory setting
Pr. 00-02
Source of the
Operation Comm and
Pr.00-15
MI/M O terminals Settings
Pr.02-01~02-08
Pr.02-13~02-22
Cont rol M ode Selection
Pr.00-09
Motor type
[PM/IM]
Setting t he related
informat ion of IM mot or
Pr. 01-00~01-02
Pr.05-01~05-04
Setting t he related
informat ion of PM motor
Pr.01-00~01-02
Pr.08-01~08-04
IM M otor Aut o-tuning
Pr.05-00
PM Motor Auto-tuning
Pr.08-00
St ep 2 Enco der setti n gs
Detection of the HOME
position of Encoder
1. us ing digital keypad
2. us ing external terminals
Setting Encodert ype
Pr.10-01~10-02
Encoder selection
Pr.10-00
St ep 4 Multi- step speed sett in gs
Setting s peed, accel/ decel. time and S curve
Pr.04-00~04-15, Pr.01-12~01-19, Pr.01-24~01-30
St ep 5 Inertia measurem ent
Trial run
Smooth test
Pr.11-00 bit0=1
Pr.11-05~11-08
1. tuning as start -up
2. tuning as stop
St ep 6 El evat or tu ni ng
Angle between magnetic field and PG origin
Pr.08-09
St ep 3 Mot or Tu nn i ng
St ep 6 Trial run
Inertia m easurement
Pr.11-01~11-05, Pr.11-14~11-15
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales