Chapter 3 Operation and Start Up
|
VFD-VL
3-7
Settings of Pr.02-
13~02-22
18: Reserved
19: Brake chopper output error
20: Warning output
21: Over voltage warning
22: Over-current stall prevention warning
23: Over-voltage stall prevention warning
24: Operation mode indication (Pr.00-15
≠
0)
25: Forward command
26: Reverse command
27: Output when current >= Pr.02-33
28: Output when current < Pr.02-33
29: Output when frequency >= Pr.02-34
30: Output when frequency < Pr.02-34
31-32: Reserved
33: Zero speed (actual output frequency)
34: Zero speed with Stop (actual output frequency)
35: Error output selection 1 (Pr.06-22)
36: Error output selection 2 (Pr.06-23)
37: Error output selection 3 (Pr.06-24)
38: Error output selection 4 (Pr.06-25)
39: Reserved
40: Speed attained (including zero speed)
41: Reserved
3.3.2.2 Step 2
Encoder settings
Selection of speed feedback cards
Please refer to appendix B.8 for details. Delta provides 4 PG cards for user to select
by their application, including EMVL-PGABL, EMVL-PGABO, EMVL-PGH01 and
EMVL-PGS01.
Pr.10-00
PG signal type
0: No function
1: ABZ
2: ABZ+Hall
3: SIN/COS+Sinusoidal
4: SIN/COS+Endat
5: SIN/COS
6: SIN/COS + Hiperface
Encoder
settings:
Pr.10-01~Pr.10-02
Detection for the magnetic pole position of motor
The detection method will be different by the setting of Pr.10-00 PG Signal Type.
The detection methods: (refer to Pr.10-00)