Chapter 4 Parameters
|
VFD-VL
4-17
4.1.11 Group 10 Speed Feedback Control Parameters
Pr.
Explanation
Settings
Factory
Setting
VF
VFPG
SVC
FO
CPG
TQ
CPG
FO
CP
M
10-00 PG Signal Type
0: No function
1: ABZ
2: ABZ+Hall
3: SIN/COS+Sinusoidal
4: SIN/COS+Endat
5: SIN/COS
6: SIN/COS + Hiperface
0
○
○ ○ ○
10-01 Encoder
Pulse
1~20000
600
○
○ ○ ○
10-02 Encoder Input Type Setting 0: Disable
1: Phase A leads in a forward run command and phase B leads
in a reverse run command
2: Phase B leads in a forward run command and phase A leads
in a reverse run command
3: Phase A is a pulse input and phase B is a direction input. (low
input=reverse direction, high input=forward direction)
4: Phase A is a pulse input and phase B is a direction input. (low
input=forward direction, high input=reverse direction)
5: Single-phase input
0
○
○ ○ ○
10-03 Encoder Feedback Fault
Treatment (PGF1, PGF2)
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and stop operation
2
○
○ ○
10-04 Detection Time for Encoder
Feedback Fault
0.00~10.0 sec
1.0
○
○ ○ ○
10-05 Encoder Stall Level (PGF3) 0~120% (0: disable)
115
○ ○ ○
○
10-06 Encoder Stall Detection
Time
0.0~2.0 sec
0.1
○ ○ ○
○
10-07 Encoder Slip Range (PGF4) 0~50% (0: disable)
50
○ ○ ○
○
10-08 Encoder Slip Detection Time 0.0~10.0 sec
0.5
○ ○ ○
○
10-09 Encoder Stall and Slip Error
Treatment
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
2
○ ○ ○
○
10-10
Mode Selection for UVW
Input
0: Z signal is at the falling edge of U-phase
1: Z signal is at the rising edge of U-phase
0
○
○ ○ ○
10-11 ASR (Auto Speed
Regulation) Control (P) of
Zero Speed
0.0~500.0% 100.0
○ ○ ○ ○
○
10-12 ASR (Auto Speed
Regulation) Control (I) of
Zero Speed
0.000~10.000 sec
0.100
○ ○ ○ ○
○
10-13 ASR (Auto Speed
Regulation) Control (P) 1
0.0~500.0% 100.0
○ ○ ○ ○
○
10-14 ASR (Auto Speed
Regulation) Control (I) 1
0.000~10.000 sec
0.100
○ ○ ○ ○
○
10-15 ASR (Auto Speed
Regulation) Control (P) 2
0.0~500.0% 100.0
○ ○ ○ ○
○
10-16 ASR (Auto Speed
Regulation) Control (I) 2
0.000~10.000 sec
0.100
○ ○ ○ ○
○
10-17 ASR 1/ASR2 Switch
Frequency
0.00~400.00Hz (0: disable)
7.00
○ ○ ○ ○
○
10-18 ASR Primary Low Pass
Filter Gain
0.000~0.350 sec
0.008
○ ○ ○ ○
○
10-19 Zero Speed Gain (P)
0~655.00%e
80.00
○
10-20 Zero Speed/ASR1 Width
Adjustment
0.0~400.00Hz 5.00
○
○
○
10-21 ASR1/ASR2 Width
Adjustment
0.0~400.00Hz 5.00
○
○
○
10-22 Zero speed Position Holding
Time
0.000~65.535 sec
0.250
○
10-23 Filter Time at Zero Speed
0.000~65.535 sec
0.004
○
10-24 Time for Executing Zero
Speed
0: after the brake release set in Pr.02-29
1: after the brake signal input (Pr.02-01~02-08 is set to 42)
0
○
10-25 Elevator Leveling (Zero
0~1000.0%
100.0
○ ○ ○ ○
○
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com