Chapter 4 Parameters
|
VFD-VL
4-27
For example, if use uses rpm to display the motor speed and the corresponding value to the 4-
pole motor 60Hz is 1800. This parameter can be set to 01800 to indicate that the
corresponding value for 60Hz is 1800rpm. If the unit is rps, it can be set 10300 to indicate the
corresponding value for 60Hz is 30.0 (a decimal point).
Only frequency setting can be displayed by the corresponding value.
After setting Pr.00-05, it won’t display the unit of frequency “Hz” after returning to the main
menu.
00-06
Software Version
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: Read Only
Settings
Read
Only
Display
#.##
00-07
Password Input
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0
Settings
1 to 9998 and 10000 to 65535
Display
0~2 (times of wrong password)
The function of this parameter is to input the password that is set in Pr.00-08. Input the correct
password here to enable changing parameters. You are limited to a maximum of 3 attempts.
After 3 consecutive failed attempts, a fault code “Password Error” will show up to force the
user to restart the AC motor drive in order to try again to input the correct password.
When forgetting password, you can decode by setting 9999 and press button
PROG
DATA
twice.
Please note that all the settings will be set to factory setting.
00-08
Password Set
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0
Settings
1 to 9998 and 10000 to 65535
Display
0
No password set or successful input in Pr. 00-07
1
Password has been set
To set a password to protect your parameter settings.
If the display shows 0, no password is set or password has been correctly entered in Pr.00-07.
All parameters can then be changed, including Pr.00-08.