Chapter 14 Fault Codes | IED-S
14-23
Action and Reset
Action
Stops urgently
Related Parameters
MI=21 DSH (Layer door safety hatch high voltage)
Reset Method
Resets automatically once the fault is cleared
Code#
KPC-CC01 Display
Fault Name
Description
F224
DSH (Layer door
safety hatch high
voltage) contact
sticking
Fault occurs when either of the following conditions
happen:
1. The door opens in the door zone, gate signal is
OFF, but DSH (Layer door safety hatch high
voltage) contact remains ON.
2. The door opens in the door zone, the door has
started to reach its open position, but DSH (Layer
door safety hatch high voltage) contact remains ON.
Action and Reset
Action
Stops urgently
Related Parameters
MI=18 GSH (Gate safety hatch high voltage),
MI=19 GSL (Gate safety hatch low voltage),
MI=21 DSH (Layer door safety hatch high voltage),
MI=100 OLT1 (Front door reaches its open position),
MI=101 OLT2 (Rear door reaches it open position)
Reset Method
Switch to the manual mode, press the RESET key on the digital keypad, press
the external reset device, or power-on again (choose either)
Code#
KPC-CC01 Display
Fault Name
Description
F225
Front door open time
exceeds
Fault occurs when IED-S does not receive any front
door open limit signal after the front door opens and
exceeds Pr.05-14 setting time
Action and Reset
Action
The front door stops opening and closes
Related Parameters
Pr.05-14 (Door Open Time Protection)
Reset Method
Resets automatically
Code#
KPC-CC01 Display
Fault Name
Description
F226
Front door close time
exceeds
Fault occurs when the elevator door does not close after
the front door closes and exceeds Pr.05-15 setting time
Action and Reset
Action
The front door stops closing and opens
Related Parameters
Pr.05-15 (Door Close Time Protection)
Reset Method
Resets automatically
Code#
KPC-CC01 Display
Fault Name
Description
F227
Rear door open time
exceeds
Fault occurs when IED-S does not receive any rear door
open limit signal after the rear door opens and exceeds
Pr.05-14 setting time
Action and Reset
Action
The rear door stops opening and closes
Related Parameters
Pr.05-14 (Door Open Time Protection)
Reset Method
Resets automatically
Summary of Contents for IED-S Series
Page 3: ......
Page 10: ...Chapter 1 Introduction IED S 1 3 1 2 Model Name 1 3 Serial Number...
Page 24: ...Chapter 2 Installation IED S 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 25: ...Chapter 2 Installation IED S 2 6 The page intentionally left blank...
Page 32: ...Chapter 3 Wiring IED S 3 7...
Page 36: ...Chapter 3 Wiring IED S 3 11 04 Main Circuit for Drive Control Asynchronous...
Page 38: ...Chapter 3 Wiring IED S 3 13 06 Safety Hatch...
Page 39: ...Chapter 3 Wiring IED S 3 14 07 Brake Circuit...
Page 42: ...Chapter 3 Wiring IED S 3 17 10 Input Contacts of Main Control Board for the Control Panel...
Page 43: ...Chapter 3 Wiring IED S 3 18 11 Output Contacts of Main Control Board for the Control Panel...
Page 44: ...Chapter 3 Wiring IED S 3 19 12 Contacts of Cartop Board OCB...
Page 45: ...Chapter 3 Wiring IED S 3 20 13 Maneuvering Box 1 16 Floor ICB...
Page 46: ...Chapter 3 Wiring IED S 3 21 14 1 Hall Call System...
Page 50: ...Chapter 3 Wiring IED S 3 25 15 Lighting Circuit...
Page 51: ...Chapter 3 Wiring IED S 3 26 16 UCMP Board Three Sensors DZU FL1 and DZD...
Page 52: ...Chapter 3 Wiring IED S 3 27 17 UCMP Board Four Sensors DZU FL1 FL2 and DZD...
Page 67: ...Chapter 5 Control Terminals IED S 5 2 5 1 Control Terminal Specifications...
Page 73: ...Chapter 5 Control Terminals IED S 5 8 The page intentionally left blank...
Page 116: ...Chapter 6 Optional Accessories IED S 6 43 EMC Filter Model No B84143D0150R127 Unit mm inch...
Page 117: ...Chapter 6 Optional Accessories IED S 6 44 EMC Filter Model No B84143D0200R127 Unit mm inch...
Page 118: ...Chapter 6 Optional Accessories IED S 6 45 EMC Filter Model No B84142A0042R122 Unit mm inch...
Page 123: ...Chapter 6 Optional Accessories IED S 6 50 The page intentionally left blank...
Page 143: ...Chapter 7 Option Cards IED S 7 20 The page intentionally left blank...
Page 151: ...Chapter 9 Digital Keypad IED S 9 4 Keypad Operation Process...
Page 201: ...Chapter 10 Auto tuning Process IED S 10 34 The page intentionally left blank...
Page 249: ...Chapter 11 Summary of Parameter Settings IED S 11 48 The page intentionally left blank...
Page 263: ...Chapter 12 Descriptions of Parameter Settings IED S 12 00 14 The page intentionally left blank...
Page 273: ...Chapter 12 Descriptions of Parameter Settings IED S 12 01 10 The page intentionally left blank...
Page 281: ...Chapter 12 Descriptions of Parameter Settings IED S 12 02 8 The page intentionally left blank...
Page 307: ...Chapter 12 Descriptions of Parameter Settings IED S 12 05 6 The page intentionally left blank...
Page 319: ...Chapter 12 Descriptions of Parameter Settings IED S 12 06 12 The page intentionally left blank...
Page 325: ...Chapter 12 Descriptions of Parameter Settings IED S 12 07 6 The page intentionally left blank...
Page 345: ...Chapter 12 Descriptions of Parameter Settings IED S 12 10 8 The page intentionally left blank...
Page 349: ...Chapter 12 Descriptions of Parameter Settings IED S 12 11 4 The page intentionally left blank...
Page 359: ...Chapter 12 Descriptions of Parameter Settings IED S 12 12 10 The page intentionally left blank...
Page 375: ...Chapter 12 Descriptions of Parameter Settings IED S 12 13 16 The page intentionally left blank...
Page 381: ...Chapter 13 Warning Codes IED S 13 6 The page intentionally left blank...
Page 415: ...Appendix A Single phase Application IED S A 4 The page intentionally left blank...
Page 417: ...Appendix B Revision History IED S B 2 The page intentionally left blank...