Chapter 10 Auto-tuning Process | IED-S
10-23
4. The usage of TCIN (traveling cable insertion), INSCP (control panel inspection switch), EIS
(emergency operation), TCI (cartop inspection switch), and INSIC (car inspection switch):
(1) Definition of Term:
a. Control panel in manual operation: signals, such as INSCP (control panel inspection
switch) and EIS (emergency operation), connected with the inspection signals in the
control panel.
b. Car in manual operation: signals, such as TCI (cartop inspection switch) and INSIC (car
inspection switch), connected with the inspection signals in the cartop board or car
command board.
c. CAR Link: the communication status between IED-S and cartop board.
(2) When to use:
TCIN
CAR
LINK
Car in manual
operation
Control panel in
manual
operation
Not in manual
operation
With TCIN
function
ON Normal
✓
✓
✓
ON Abnormal
OFF Normal
✓
OFF Abnormal
✓
Without TCIN
function
X Normal
✓
✓
X Abnormal
✓
5. Speed for different modes: In manual operation mode, the elevator runs with Pr.04-05 (Leveling
Speed) within Pr.04-18 (Low-speed Running Time When Enabled Manually) setting time. In
inspection mode, the elevator runs with Pr.04-01 (Inspection Speed). In emergency operation
mode, the elevator runs with Pr.04-04 (Non-leveling Speed). If the first one upward or downward
forced deceleration activates in the manual operation mode, the elevator runs with Pr.04-04
(Non-leveling Speed) instead. If the upper leveling, or lower leveling, or door zone switch
activates in the manual operation mode, the elevator runs with Pr.04-05 (Leveling Speed)
instead.
6. Reset procedures of inspection from pit:
When in the mode of inspection from pit, the elevator does not change to automatic mode simply
because you switch the mode from pit inspection to automatic, unless you complete the steps
below:
(1) Change the pit inspection switch to automatic on the precondition that the safety hatch is
OFF, layer door safety hatch is OFF, and external reset device is not pressed.
(2) Switch the safety hatch to normal.
(3) Close the layer door.
(4) Press the external reset device to complete the reset. Or you can press the hall call button at
the bottom floor for three to six seconds and release it after layer door closes (step (3)) for
30 seconds. Pressing and holding it too long or too short does not work. Then, the elevator
changes to automatic mode successfully.
(5) If you set them incorrectly, you only have to repeat steps (1) to (4) after switching the pit
inspection switch to inspection.
Summary of Contents for IED-S Series
Page 3: ......
Page 10: ...Chapter 1 Introduction IED S 1 3 1 2 Model Name 1 3 Serial Number...
Page 24: ...Chapter 2 Installation IED S 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 25: ...Chapter 2 Installation IED S 2 6 The page intentionally left blank...
Page 32: ...Chapter 3 Wiring IED S 3 7...
Page 36: ...Chapter 3 Wiring IED S 3 11 04 Main Circuit for Drive Control Asynchronous...
Page 38: ...Chapter 3 Wiring IED S 3 13 06 Safety Hatch...
Page 39: ...Chapter 3 Wiring IED S 3 14 07 Brake Circuit...
Page 42: ...Chapter 3 Wiring IED S 3 17 10 Input Contacts of Main Control Board for the Control Panel...
Page 43: ...Chapter 3 Wiring IED S 3 18 11 Output Contacts of Main Control Board for the Control Panel...
Page 44: ...Chapter 3 Wiring IED S 3 19 12 Contacts of Cartop Board OCB...
Page 45: ...Chapter 3 Wiring IED S 3 20 13 Maneuvering Box 1 16 Floor ICB...
Page 46: ...Chapter 3 Wiring IED S 3 21 14 1 Hall Call System...
Page 50: ...Chapter 3 Wiring IED S 3 25 15 Lighting Circuit...
Page 51: ...Chapter 3 Wiring IED S 3 26 16 UCMP Board Three Sensors DZU FL1 and DZD...
Page 52: ...Chapter 3 Wiring IED S 3 27 17 UCMP Board Four Sensors DZU FL1 FL2 and DZD...
Page 67: ...Chapter 5 Control Terminals IED S 5 2 5 1 Control Terminal Specifications...
Page 73: ...Chapter 5 Control Terminals IED S 5 8 The page intentionally left blank...
Page 116: ...Chapter 6 Optional Accessories IED S 6 43 EMC Filter Model No B84143D0150R127 Unit mm inch...
Page 117: ...Chapter 6 Optional Accessories IED S 6 44 EMC Filter Model No B84143D0200R127 Unit mm inch...
Page 118: ...Chapter 6 Optional Accessories IED S 6 45 EMC Filter Model No B84142A0042R122 Unit mm inch...
Page 123: ...Chapter 6 Optional Accessories IED S 6 50 The page intentionally left blank...
Page 143: ...Chapter 7 Option Cards IED S 7 20 The page intentionally left blank...
Page 151: ...Chapter 9 Digital Keypad IED S 9 4 Keypad Operation Process...
Page 201: ...Chapter 10 Auto tuning Process IED S 10 34 The page intentionally left blank...
Page 249: ...Chapter 11 Summary of Parameter Settings IED S 11 48 The page intentionally left blank...
Page 263: ...Chapter 12 Descriptions of Parameter Settings IED S 12 00 14 The page intentionally left blank...
Page 273: ...Chapter 12 Descriptions of Parameter Settings IED S 12 01 10 The page intentionally left blank...
Page 281: ...Chapter 12 Descriptions of Parameter Settings IED S 12 02 8 The page intentionally left blank...
Page 307: ...Chapter 12 Descriptions of Parameter Settings IED S 12 05 6 The page intentionally left blank...
Page 319: ...Chapter 12 Descriptions of Parameter Settings IED S 12 06 12 The page intentionally left blank...
Page 325: ...Chapter 12 Descriptions of Parameter Settings IED S 12 07 6 The page intentionally left blank...
Page 345: ...Chapter 12 Descriptions of Parameter Settings IED S 12 10 8 The page intentionally left blank...
Page 349: ...Chapter 12 Descriptions of Parameter Settings IED S 12 11 4 The page intentionally left blank...
Page 359: ...Chapter 12 Descriptions of Parameter Settings IED S 12 12 10 The page intentionally left blank...
Page 375: ...Chapter 12 Descriptions of Parameter Settings IED S 12 13 16 The page intentionally left blank...
Page 381: ...Chapter 13 Warning Codes IED S 13 6 The page intentionally left blank...
Page 415: ...Appendix A Single phase Application IED S A 4 The page intentionally left blank...
Page 417: ...Appendix B Revision History IED S B 2 The page intentionally left blank...