4.4.3 Digital input diagnosis operation
You can switch to the Diagnosis mode by the following steps. When DI1 - DI9 are triggered by
the external signal, the panel shows the corresponding signal in bit. When it shows 1, it means
the DI is on.
For example, if it shows 1FE1, E is in hexadecimal format; it will be 1110 when it transfers to
binary format. Then, DI6 - DI8 are on.
SET
1 1 1 1 1 1 1 1 0 0 0 0 1
13
12 11 10 9
8
7
6
5
4
3 2
1
Corresponding
DI status
Binary code
The panel displays in
hexadecimal format.
(Display in hexadecimal format)
4.4.4 Digital output diagnosis operation
You can switch to the Diagnosis mode by the following steps. When DO1 - DO6 are triggered by
the output signal, the panel shows the corresponding signal in bit. When it shows 1, it means
the DO is on.
For example, if it shows 1F, F is in hexadecimal format; it will be 1111 when it transfers to binary
format. Then, DO1 - DO4 are on.
SET
0 0 0 1 1 1 1 1
5
4
3
2
1
Corresponding
DO status
Binary code
The panel displays in
hexadecimal format
(Display in hexadecimal format)
Summary of Contents for ASDA-B3 Series
Page 15: ... This page is intentionally left blank ...
Page 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Page 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Page 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Page 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Page 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Page 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Page 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Page 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Page 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...