ASDA-B3 Motion Control
7-63
7
Normally open
P5.039.Z = 0
Normally closed
P5.039.Z = 1
7890
CAP axis position
P5.037
CAP switch
P5.039.X Bit 0
Start address
P5.036
CAP
amount
P5.038
CN1 P5.039.Y = 2
CN2 P5.039.Y = 3
CAP axis source
CAP triggering logic
CAP completed?
P5.038==0
Yes
No
Reset the 1
st
position
P5.039.X Bit 1 = 1
1
st
position = P5.076
Enable CMP after the 1
st
data
is captured
P5.039.X Bit 2 = 1
Cyclic CAP
P1.019.X = 1
P5.038 = default value
Call PR#50
P5.039.X Bit 3 = 1
Data array
1234
2345
5678
6789
7890
DI4
DI4
CAP amount
P5.038 = P5.038 - 1
Figure 7.2.2.1 Flowchart for high-speed position capturing