ASDA-B3 MODBUS Communication
9-7
9
Example 2: function code 06H, write single word
When the master issues a write command to the first slave:
The slave writes data 0064H to the start data address 0200H and sends a response message
to the master after writing is complete.
ASCII mode:
Command Message (Master):
Response Message (Slave):
Start
‘:’
Start
‘:’
Slave Address
‘0’
Slave Address
‘0’
‘1’
‘1’
Function
‘0’
Function
‘0’
‘6’
‘6’
Start Data Address
‘0’
Start Data Address
‘0’
‘2’
‘2'
‘0’
‘0’
‘0’
‘0’
Data Content
‘0’
Data Content
‘0’
‘0’
‘0’
‘6’
‘6’
‘4’
‘4’
LRC
‘9’
LRC
‘9’
‘3’
‘3’
End 1
(0DH) (CR)
End 1
(0DH) (CR)
End 0
(0AH) (LF)
End 0
(0AH) (LF)
RTU mode:
Command Message (Master):
Response Message (Slave):
Address
01H
Address
01H
Slave Function
06H
Slave Function
06H
Start Data Address
02H (High)
Start Data Address
02H (High)
00H (Low)
00H (Low)
Data Content
00H (High)
Data Content
00H (High)
64H (Low)
64H (Low)
CRC (Check Low)
89H (Low)
CRC (Check Low)
89H (Low)
CRC (Check High)
99H (High)
CRC (Check High)
99H (High)
Note: a silent interval of 10 ms is required before and after each transmission in RTU mode.
Summary of Contents for ASDA-B3 Series
Page 15: ... This page is intentionally left blank ...
Page 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Page 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Page 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Page 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Page 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Page 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Page 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Page 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Page 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...