ASDA-B3 Motion Control
7-9
7
7.1.3 Motion Control commands
The ASDA-B3 provides 100 path setting sets, which include the homing method, Speed
command, Position command, Jump command, Write command, and Index Position command.
The following sections detail each command type.
7.1.3.1 Homing methods
The ASDA-B3 provides 11 homing methods in the PR mode, including home sensor, limit, and
hard stop as the reference origin. They come with sub-selections such as whether to refer to the
Z pulse and the limit signal as the trigger, with more than 30 combinations available. The
homing method is specified by P5.004 and the homing definition is determined by P6.000.
The following lists the function of each bit.
P5.004
Homing methods
Address: 0508H
0509H
Default:
0x0000
Control mode: PR
Unit:
-
Setting range: 0x0000 - 0x012A
Format:
HEX
Data size:
16-bit
Settings:
Y
Z
U
X
X
Homing method
Z
Limit setting
Y
Z pulse setting
U
Reserved
Definition of each setting value:
U
Z
Y
X
Reserved
Limit setting
Z pulse setting
Homing method
-
0 - 1
0 - 2
0 - 8
-
Y = 0: return to Z pulse
Y = 1: go forward to Z pulse
Y = 2: do not look for Z pulse
X = 0: homing in forward direction and define
the positive limit as the homing origin
X = 1: homing in reverse direction and define
the negative limit as the homing origin
When reaching the limit:
Z = 0: show error
Z = 1: reverse direction
X = 2: homing in forward direction, ORG:
OFF
ON as the homing origin
X = 3: homing in reverse direction, ORG:
OFF
ON as the homing origin
-
X = 4: look for Z pulse in forward direction
and define it as the homing origin
X = 5: look for Z pulse in reverse direction
and define it as the homing origin
Y = 0: return to Z pulse
Y = 1: go forward to Z pulse
Y = 2: do not look for Z pulse
X = 6: homing in forward direction, ORG:
ON
OFF as the homing origin
X = 7: homing in reverse direction, ORG:
ON
OFF as the homing
origin
Summary of Contents for ASDA-B3 Series
Page 15: ... This page is intentionally left blank ...
Page 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Page 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Page 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Page 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Page 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Page 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Page 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Page 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Page 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...