ASDA-A3 Parameters
8-43
8
P1.026
Low-frequency vibration suppression gain (1)
Address: 0134H
0135H
Default:
0
Control mode: PT / PR
Unit:
-
Setting range: 0 - 9
Format:
DEC
Data size:
16-bit
Settings:
To set the gain of the first low-frequency vibration suppression, increase the value to improve the position
response. If you set the value too high, the motor may not operate smoothly. The suggested value is 1.
Set P1.026 to 0 to disable the first low-frequency vibration suppression filter.
P1.027
Low-frequency vibration suppression frequency (2)
Address: 0136H
0137H
Default:
1000
Control mode: PT / PR
Unit:
0.1 Hz
Setting range: 10 - 1000
Format:
DEC
Data size:
16-bit
Example:
150 = 15 Hz
Settings:
Sets the second low-frequency vibration suppression frequency. When you set P1.028 to 0, the second
low-frequency vibration suppression filter is disabled.
P1.028
Low-frequency vibration suppression gain (2)
Address: 0138H
0139H
Default:
0
Control mode: PT / PR
Unit:
-
Setting range: 0 - 9
Format:
DEC
Data size:
16-bit
Settings:
To set the gain of the second low-frequency vibration suppression, increase the value to improve the
position response. If you set the value too high, the motor may not operate smoothly. The suggested
value is 1. Set P1.028 to 0 to disable the second low-frequency vibration suppression filter.
P1.029
Auto low-frequency vibration suppression mode
Address: 013AH
013BH
Default:
0
Control mode: PT / PR
Unit:
-
Setting range: 0 - 1
Format:
DEC
Data size:
16-bit
Settings:
0: disable the automatic low-frequency vibration detection function.
1: disable the function automatically after vibration suppression. The value resets to 0 automatically.
Summary of Contents for ASDA-A3 Series
Page 15: ... This page is intentionally left blank ...
Page 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Page 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Page 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Page 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Page 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Page 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Page 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Page 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Page 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Page 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...