A.2.4 Overload features
Definition of overload protection
The overload protection prevents the motor from overheating.
Causes of overloading
1.
The motor’s rated torque exceeds the rated range and the operation time is too long.
2. The inertia ratio is too high and the motor frequently accelerates and decelerates.
3. An incorrect connection between the power cable and the encoder wiring.
4. Incorrect servo gain setting causes resonance in the motor.
5. You operate a motor with a built-in brake without releasing the brake.
Graph of load and operating time
Low inertia (ECM-A3L series), high inertia (ECM-A3H series)
Load
Operating time
120%
263.8 s
140%
35.2 s
160%
17.6 s
180%
11.2 s
200%
8 s
220%
6.1 s
240%
4.8 s
260%
3.9 s
280%
3.3 s
300%
2.8 s
350%
2.1 s
Summary of Contents for ASDA-A3 Series
Page 15: ... This page is intentionally left blank ...
Page 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Page 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Page 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Page 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Page 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Page 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Page 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Page 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Page 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Page 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...