ASDA-A3 CANopen Mode
12-43
12
Sub-index
2
Description
Reception type
Data format
UNSIGNED8
Access
RW
PDO mapping
No
Setting range
UNSIGNED8
Default
0
Object function:
The type setting is as follows
Setting value
Transmission type
Cyclic
Acyclic
Synchronous
Asynchronous
RTR only
00h (0)
V
V
01h
- F0h
(1 - 240)
V
V
F1h
- FBh
(241 - 251)
Reserved
FCh (252)
V
V
FDh (253)
V
V
FEh (254)
V
FFh (255)
V
Sub-index
3
Description
Inhibit time (not used for RPOD)
Data format
UNSIGNED16
Access
RW
PDO mapping
No
Setting range
UNSIGNED16
Default
0
Sub-index
4
Description
Compatibility entry
Data format
UNSIGNED8
Access
RW
PDO mapping
No
Setting range
UNSIGNED8
Default
0
Sub-index
5
Description
Event timer (not used for RPDO)
Data format
UNSIGNED16
Access
RW
PDO mapping
No
Setting range
UNSIGNED16
Default
0
Summary of Contents for ASDA-A3 Series
Page 15: ... This page is intentionally left blank ...
Page 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Page 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Page 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Page 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Page 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Page 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Page 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Page 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Page 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Page 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...