Operation Mode
ASDA-A3
6-10
6
6.2.6 Low-pass filter
Target
position
P1.008
Refer to Chapter 8 for detailed descriptions of the relevant parameter.
Parameter
Function
P1.008
Position command smoothing constant (low-pass filter)
6.2.7 Timing diagram of PR mode
In PR mode, the Position command is issued with the DI signals (POS0 – POS6 and CTRG) for
CN1. Refer to Section 6.2.2 for information about the DI signal and its selected register.
The timing diagrams are shown below.
PR#1
Internal
register
(PR#0 - 99)
1 ms
on
off
off
off
on
on
off
off
on
Set the response time with
P2.009
POS 0
POS 1
POS 2
CTRG
SON
External
DI
on
on
on
off
off
off
Cmd_OK
TPOS
MC_OK
Internal
DO
PR#2
PR#4
Motion
curve
(Speed)
Note: Cmd_OK is on when the PR command completes; TPOS is on when the error is smaller than value
set by P1.054; MC_OK is on when Cmd_OK and TPOS are both on.
Summary of Contents for ASDA-A3 Series
Page 15: ... This page is intentionally left blank ...
Page 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Page 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Page 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Page 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Page 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Page 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Page 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Page 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Page 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Page 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...