E1420
CPU Bus parity
error. Power
cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E1422
CPU # machine
check error.
Power
cycle AC.
The system BIOS has
reported a machine
check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E1610
Power Supply #
(### W)
missing.
Check power
supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supply" on
page 151.
E1614
Power Supply #
(### W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supply" on
page 151.
E1618
Predictive
failure on
Power Supply #
(### W).
Check PSU.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See "Troubleshooting
Power Supply" on
page 151.
E161C
Power Supply #
(### W) lost
AC power.
Check PSU
cables.
Specified power supply is
attached to the system,
but it has lost its
AC input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supply" on page 151.
Table 1-2.
LCD Status Messages (Optional)
(continued)
Code
Text
Causes
Corrective Actions