324
V i e w i n g S t a t i s t i c s
www
.dell.com | support.dell.com
N e w A l a r m E n t r y
3
Define the
New Alarm Index, Sample Variable, Sample Type, Rising Threshold,
Rising Event, Falling Threshold, Falling Event, Startup Alarm, Interval
, and
Owner
fields.
4
Click
Apply Changes
. The RMON alarm is added, and the device is updated.
Modifying an Alarm Table entry:
1
Open the
RMON Alarm
page.
2
Select an
RMON Alarm Table
entry in the
Alarm Entry
drop-down box.
3
Modify the
Sample Type, Rising Threshold, Rising Event, Falling Threshold, Falling
Event, Startup Alarm, Interval
, and/or
Owner
fields.
4
Click
Apply Changes
. The
RMON Alarm Table
entry is modified, and the device is
updated.
Displaying the Alarm Table:
1
Open the
RMON Alarm Table
.
2
Click
Show All
. The
RMON Alarm Table
opens.