C o n f i g u r i n g S w i t c h I n f o r m a t i o n
211
–
Disable
—Disables auto negotiation on the port. This is the default value.
–
Current Auto Negotiation
—Indicates the Auto Negotiation operational status.
•
Back Pressure
—Enables Back Pressure mode on the device. Back Pressure mode is
used with Half Duplex mode to disable ports from receiving messages. When Back
Pressure is enabled, Head-of-Line blocking is not operational, even if it is set to enable.
•
The possible field values are:
–
Enable
—Enables back pressure on the port.
–
Disable
—Disable back pressure on the port. This is the default value.
–
Current Back Pressure
—Indicates the back pressure operational status.
•
Flow Control
—Indicates if Flow Control is enabled on the port. Flow control is
enabled if the device is in Duplex mode. In addition, when Flow Control is enabled,
Head-of-Line is disabled on the selected port. When Flow Control is enabled, Head-
of-Line blocking is not operational, even if it is set to enable. The possible field values
are:
–
Enable
—Indicates that Flow Control is enabled on the device.
–
Disable
—Indicates that Flow Control is disabled on the device. This is the
default value.
–
Current Flow Control
—Indicates the Flow Control operational status.
–
Auto-negotiation
—Enables auto negotiation of Flow Control on the port.
–
Tx Only
—Enables auto negotiation for egress ports.
–
Rx Only
—Enables auto negotiation for ingress ports.
•
MDI/MDIX
—Allows the device to decipher between crossed and uncrossed cables.
Hubs and switches are deliberately wired the opposite way end stations are wired, so
that when a hub or switch is connected to an end station, a straight through Ethernet
cable can be used, and the pairs match up properly. When two hubs/switches are
connected to each other, or two end stations are connected to each other, a crossover
cable is used to make sure that the correct pairs are connected. The standard cable
wirings are:
–
Media Dependent Interface with Crossover (MDIX) for hubs and switches
–
Media Dependent Interface (MDI) for end stations
NOTE:
Auto MDIX does not operate on FE ports when auto negotiation is disabled.