I n s t a l l i n g t h e Po w e r C o n n e c t 3 3 2 4 / 3 3 4 8 S w i t c h
35
C o n n e c t i n g P o w e r C o n n e c t 3 3 2 4 / 3 3 4 8 t o a P o w e r S u p p l y
•
Plug in the PowerConnect 3324/3348 to one of the previously listed power sources.
AC Power Connection
AC power should be supplied to the unit through a 1.5m (5 foot) standard power cable with
safety-ground connected.
To connect power to PowerConnect 3324/3348:
1
Connect the power cable to the AC main socket located on the rear panel. If there is a
redundant power module, connect this redundant power module cable to a separate
power supply.
2
Connect the power cable to a grounded AC outlet.
3
Confirm that the device is connected and operating correctly by examining the LEDs
on the front panel. For more information about LEDs, see "
LED Definitions
".
Cable, Port, and Pinout Information
This section describes the PowerConnect 3324/3348 physical interfaces and provides
information about cable connections. Stations are connected to PowerConnect 3324/3348
ports through the physical interface ports on the front panel. For each station, the
appropriate mode (Half/Full Duplex, Auto) is set.