Nominal mains voltage
Nominal current
Enclosure size
0062
FR8
0080
0100
0125
FR9
0144
0177
0205
0261
FR10 Standalone
0325
0385
0416
0460
FR11 Standalone
0502
0590
3.6 Available Protection Ratings
Table 4: Available Protection Ratings
Mains voltage
Enclosure size
IP21 (UL Type 1)
IP54 (UL Type 12)
208–240 V
FR4–FR9
x
x
350–500 V
FR4–FR9
x
x
350–500 V
FR10 Standalone
x
x
350–500 V
FR11 Standalone
x
–
525–690 V
FR4-FR9
x
x
525–690 V
FR10 Standalone
x
x
525–690 V
FR11 Standalone
x
–
3.7 Available EMC Classes
The product standard (EMC immunity requirements) IEC/EN 61800-3 + A1 has 5 categories. The VACON
®
AC drives are divided into 5
EMC classes that have equivalents in the standard. All VACON
®
NX AC drives comply with the standard IEC/EN 61800-3 + A1.
The type code tells which category requirement the AC drive complies with (see
3.4 Description of the Type Code
).
AQ275638903263en-000601 / DPD00910
22 | Danfoss A/S © 2022.12
Product Overview
VACON® NXS/NXP Air-cooled
Operating Guide