Technical item or function
Technical data
FR8: 58
FR9–FR11: 76
Functional safety
Hardware based ‘Safe Torque
Off’ safety function to prevent
the drive from generating torque
on the motor shaft.
STO safety function has been de-
signed for use in accordance
with the following standards
EN 61800-5-2 Safe Torque Off (STO) SIL3
EN ISO 13849-1 PL “e” Category 3
EN 62061 SILCL3
IEC 61508 SIL3
The function also corresponds to an uncontrolled stop in accord-
ance with stop category 0, EN 60204-1.
EN 954-1, Category 3
SS1 safety function is realized in
compliance with type C of the
drives safety standard
EN61800-5-2 (Type C: “The
PDS(SR) initiates the motor de-
celeration and initiates the STO
function after an application-
specific time delay”).
SS1 safety function has been de-
signed for use in accordance
with the following standards:
EN 61800-5-2 Safe Stop 1 (SS1) SIL3
EN ISO 13849-1 PL "e" Category 3
EN 62061 SILCL3
IEC 61508 SIL3
The function also corresponds to a controlled stop in accordance
with stop category 1, EN60204-1.
ATEX thermistor input
94/9/EC, CE 0537 Ex 11 (2) GD
Approvals
–
CE, cULus, RCM, KC, EAC, UA. (See the nameplate of the drive for more
approvals.) Marine approvals: LR, BV, DNVGL, ABS, RMRS, CCS, KR, NK.
Efficiency
–
Control connections
(apply to boards OP-
TA1, OPTA2, and
OPTA3)
Analog input voltage
0…+10 V, Ri = 200 kΩ, (–10 V…+10 V joystick control)
Resolution 0.1% (VACON
®
NXP: 12-bit, VACON
®
NXS: 10-bit), accuracy
±1%
Analog input current
0(4)-20 mA, Ri = 250 Ω differential
Digital inputs (6)
Positive or negative logic; 18–30 V DC
Auxiliary voltage
+24 V, ±10%, max volt. ripple < 100 mV rms; maximum 250 mA
Dimensioning: Maximum 1000 mA/control box (power back-up)
Output reference voltage
+10 V, +3%, maximum load 10 mA
Analog output
0(4)–20 mA; RL maximum 500 Ω; Resolution 10 bit; Accuracy ±2%
Digital outputs
Open collector output, 50 mA/48 V
Relay outputs
2 programmable change-over relay outputs
Switching capacity (resistive): 24 VDC/8 A, 250 VAC/8 A, 125 VDC/
0.4 A
Min.switching load: 5 V/10 mA
AQ275638903263en-000601 / DPD00910
166 | Danfoss A/S © 2022.12
Specifications
VACON® NXS/NXP Air-cooled
Operating Guide