Code
Description
P = Standard and input swithc UL (Standalone)
K = DC link connectors and input switch UL (standalone)
The mounting, the second letter: (x
X
x):
S = Air-cooled drive
The boards, the third letter (xx
X
):
S = Standard boards (FR4 to FR8)
V = Coated boards (FR4 to FR8)
F = Standard boards (FR9 to FR11)
G = Coated boards (FR9 to FR11)
A = Fiber, Integrated control (FR10 to FR11 standalone drives)
B = Fiber, Integrated control, Coated boards (FR10 to FR11 standalone drives)
N = separate IP54 (UL Type 12) control box, standard boards, fiber connection (FR9 IP00, ≥ FR10)
O = separate IP54 (UL Type 12) control box, coated boards, fiber connection (FR9 IP00, ≥ FR10)
X = separate IP00 control box, standard boards (FR9 IP00)
Y = separate IP00 control box, coated boards (FR9 IP00)
A1A2C30000 The option boards. 2 characters for each slot. 00 = the slot is not used
The option board abbreviations:
A = basic I/O board
B = expander I/O board
C = fieldbus board
D = special board
E = fieldbus board
For example, E3 = PROFIBUS DP
+DNOT
The optional codes. See full list of option codes in the VACON
®
NXP Selection Guide.
1
A brake resistor is available as an option for external installation for 208–240 V (FR7–FR11), 380–500 V (FR7–FR11), and 525–690 V (all enclosure
sizes).
3.5 Enclosure Sizes
Example
The codes for nominal current and nominal mains voltage are part of the type code (see
3.4 Description of the Type Code
). Use these values to find out the enclosure size of the AC drive from the table.
In the example "NXP
00035
-A2H1SSS-A1ADNOT", the code for nominal current is 0003 and the code for nominal mains
voltage is 5.
Table 3: Enclosure Sizes
Nominal mains voltage
Nominal current
Enclosure size
2 (208–240 V)
0003
FR4
0004
0007
0008
AQ275638903263en-000601 / DPD00910 | 19
Danfoss A/S © 2022.12
Product Overview
VACON® NXS/NXP Air-cooled
Operating Guide