background image

CABINET LIGHTING

RETROFIT INSTALLATION GUIDE

UNIQUE

LIGHTING

SOLUTIONS

Summary of Contents for USLED

Page 1: ...CABINET LIGHTING RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS ...

Page 2: ... property this product must be installed in accordance to National Electric Code in the US or Canadian Electrical Code CSA22 1 in Canada Disconnect power before installing the product or servicing it Wait until the lamp s have cooled down before retrofitting or servicing the fixture The retrofit kit is to be installed only in UL Listed signs US LED Channel Letter modules are only to be used with t...

Page 3: ...per Wires RLSW 24 Pair of 24 Quick Connect Jumper Wires RLSW 36 Pair of 36 Quick Connect Jumper Wires Class 2 Power Supply 24VDC Figure 5 PSA 24 80 Advance model number LED120A0024V33F 24VDC 80W power supply PSA 24 100 Advance model number LEDINTA0024V41FO 24VDC 100W power supply 8 self drilling screws Figure 6 Wire nuts Figure 7 REQUIRED TOOLS Drill 125 1 8 drill bit 250 1 4 nut driver Saw for cu...

Page 4: ...lengths of 6 a Cut wires midway between modules b Cut extrusion 90 degrees to the unit length using any saw designed to cut aluminum Do not cut through module If desired length is behind a module loosen the screw and slide the module to clear the cut line 5 Designed to be stacked end to end a Slide rail clip into center slot of two Tandem units b Push or tap units together until the two extrusions...

Page 5: ...rom the sign face and the Tandem units are symmetrically spaced between 9 to 12 apart along the top for vertical applications or the left side for horizontal applications If mounting bracket interferes with fluo rescent socket slightly offset bracket to clear the socket Figure 10 7 Place Tandem unit in sign by first inserting a mounting bracket into the middle slot Figure 11 then place the middle ...

Page 6: ... Wires between Power Supply and Tandem unit module tabs minimum 1 18AWG wire with 1 20AWG maximum 4 16AWG with 1 20 AWG Red wire to the positive tab Blue wire to the negative tab of the Tandem module See Wiring Diagram on Page 7 14 Use 6 Quick Connect Jumper Wires to energize Tandem units within the same row column Red wire to the positive tabs Blue wire to the negative tabs of the Tandem modules ...

Page 7: ...oning power source C Short D Overload Replace bad module by cutting the blue and red wires on both ends of the bad module Detach bad module from the aluminum extrusion and replace with a new functioning module Use wire nuts to splice wires on both ends of the new module to the adjacent modules A Adjust loads on power sources to be within recommended limits B Replace power source A Restore connecti...

Reviews: