Specifications
SiEN18-622
46
Specifications
60Hz 220V
Note:
The operating sound is based on the rear side suction inlet and the external static pressure 30 Pa.
Operating sound for under side suction inlet : [operating sound for rear side suction inlet] +6 dB.
However, when installation to which the external static pressure becomes low is carried out,
6 dB or more may go up.
Model
CDXS25EAVMT
CDXS35EAVMT
Cooling
Heating
Cooling
Heating
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
—
—
Air Flow Rates
m³/min
(cfm)
H
8.7 (307)
8.7 (307)
8.7 (307)
8.7 (307)
M
8.0 (282)
8.0 (282)
8.0 (282)
8.0 (282)
L
7.3 (258)
7.3 (258)
7.3 (258)
7.3 (258)
SL
6.2 (219)
6.2 (219)
6.2 (219)
6.2 (219)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
62
62
Speed
Steps
5 Steps, Silent, Auto
5 Steps, Silent, Auto
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.52
0.52
0.52
0.52
Power Consumption (Rated)
W
72
72
72
72
Power Factor
%
62.9
62.9
62.9
62.9
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
200×700×620
200×700×620
Packaged Dimensions (H×W×D)
mm
274×906×751
274×906×751
Weight
kg
21
21
Gross Weight
kg
29
29
Operation
Sound
H/M/L/SL
dBA
35/33/31/29
35/33/31/29
35/33/31/29
35/33/31/29
External Static Pressure
Pa
30
30
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
VP20 (O.D.
φ
26 / I.D.
φ
20)
VP20 (O.D.
φ
26 / I.D.
φ
20)
Drawing No.
3D052113
3D052114
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for FTKS50BVMB
Page 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Page 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Page 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Page 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Page 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Page 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Page 452: ...SiEN18 622 vi Index ...