Specifications
SiEN18-622
20
Specifications
1.1.2 BP Units
50Hz 220-230-240V
Note:
1. BP or Indoor Unit Max. Height - BP or Indoor Unit Min. Height
→
Max. 15m.
Set up BP and indoor unit within 15m height difference.
2. The piping connection must be cut so as to suit the piping sizes of the indoor unit which will be connected.
The same sizes should be used for the piping on the outdoor unit.
3. ( )* : including auxiliary piping length
Model
BPMKS967A2
BPMKS967A3
Connectable Indoor Units
1~2 Units
1~3 Units
Casing Color
Paintingless
Power Consumption
W
10
10
Running Current
A
0.05
0.05
Refrigerant Type
R-410A
Dimension (H×W×D)
mm
180×294(650)*×350
Package Dimension (H×W×D)
mm
257×738×427
Machine Weight
kg
7.5
8
Gross Weight
kg
11
12
Number of Wiring Connections
4 for Interunit Wiring
Piping
Connection
(Brazing)
Liquid
mm
Main :
φ
9.5×1 / Branch :
φ
6.4×2
Main :
φ
9.5×1 / Branch :
φ
6.4×3
Gas
mm
Main :
φ
19.1×1 / Branch :
φ
15.9×2
Main :
φ
19.1×1 / Branch :
φ
15.9×3
Drain
mm
Drain Processingless
Heat Insulation
Both Liquid and Gas Pipes
Max. Piping Length
m
—
Amount of Additional Charge
g/m
—
Max. Height Difference
m
—
Max. Combination
kW
14.2
20.8
Min. Combination
kW
2.5
2.5
Accessories
Installation Manual
pc.
1
L Shape Reducer
pc.
For Main
Liquid
1 (For I.D.
φ
6.4)
Gas
1 (For I.D.
φ
12.7)
Gas
1 (For I.D.
φ
15.9, 19.1)
For Branch
Liquid
2 (For I.D.
φ
12.7, 9.5)
3 (For I.D.
φ
12.7, 9.5)
Gas
1 (For I.D.
φ
9.5)
Hanger Metal
pc.
4
Screws
pc.
8 (M4×8)
Heat Insulation (2pc. is 1 set)
3 Set
4 Set
Binding Band
pc.
2
Drawing No.
4D050057B
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for FTKS50BVMB
Page 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Page 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Page 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Page 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Page 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Page 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Page 452: ...SiEN18 622 vi Index ...