SiEN18-622
Instruction
System Configuration
251
FILTERS
1. Open the front grille.
2. Pull out the air filters.
•
Push upwards the tab at the center of each
air filter, then pull it down.
3. Take off the air purifying filter, photocatalytic
deodorizing filter.
•
Hold the recessed parts of the frame and
unhook the four claws.
4. Clean or replace each filter.
•
See below.
5. Set the air filter, air purifying filter and
photocatalytic deodorizing filter as they were
and close the front grille.
•
Insert claws of the filters into slots of the front
grille.
•
Push the grille at the 5 points
Air Filter
1. Wash the air filters with water or clean them
with vacuum cleaner.
•
If the dust does not come off easily, wash
them with neutral detergent thinned with
lukewarm water, then dry them up in the
shade.
•
It is recommended to clean the air filters
every two weeks.
Air Purifying Filter (green)
(Replace approximately once every 3 months.)
1. Detach the filter element and attach a new
one.
•
Insert with the green side up.
•
It is recommended to replace the air
purifying filter every three months.
Photocatalytic Deodorizing Filter (gray)
[Maintenance]
1. Dry the photocatalytic deodorizing filter in the sun.
•
After removing the dust with a vacuum cleaner, place the filter in the sun for approximately 6
hours. By drying the photocatalytic deodorizing filter in the sun, its deodorizing and antibacterial
capabilities are regenerated.
•
Because the filter material is paper, it can not be cleaned with water.
•
It is recommended dry the filter once every 6 months.
[Replacement]
1. Detach the filter element and attach a new one.
Air p
u
rifying filter
or Photoc
a
t
a
lytic
deodorizing filter
Summary of Contents for FTKS50BVMB
Page 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Page 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Page 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Page 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Page 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Page 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Page 452: ...SiEN18 622 vi Index ...