SiEN18-622
Specifications
Specifications
37
1.2.3 Indoor Units
Wall Mounted Typ
e
50Hz 220-230-240V / 60Hz 220-230V
Model
FTXS20DVMA
FTXS25DVMA
Cooling
Heating
Cooling
Heating
Rated Capacity
2.0kW Class
2.5kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
8.7 (307)
9.4 (332)
8.7 (307)
9.4 (332)
M
6.7 (237)
7.6 (268)
6.7 (237)
7.6 (268)
L
4.7 (166)
5.8 (205)
4.7 (166)
5.8 (205)
SL
3.9 (138)
5.0 (177)
3.9 (138)
5.0 (177)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
40
Speed
Steps
5 Steps, Silent, Auto
5 Steps, Silent, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.17-0.16-0.15 / 0.17-0.16
0.17-0.16-0.15 / 0.17-0.16
0.17-0.16-0.15 / 0.17-0.16
0.17-0.16-0.15 / 0.17-0.16
Power Consumption (Rated)
W
35-35-35 / 35-35
35-35-35 / 35-35
35-35-35 / 35-35
35-35-35 / 35-35
Power Factor
%
93.6-95.1-97.2 / 93.6-95.1
93.6-95.1-97.2 / 93.6-95.1
93.6-95.1-97.2 / 93.6-95.1
93.6-95.1-97.2 / 93.6-95.1
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
283×800×195
283×800×195
Packaged Dimensions (H×W×D)
mm
265×855×340
265×855×340
Weight
kg
9
9
Gross Weight
kg
12
12
Operation
Sound
H/M/L/SL
dBA
37/-/25/22
37/-/28/25
37/25/22
37/28/25
Sound Power
H
dBA
—
—
—
—
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D049290
3D049291
Model
FTXS35DVMA
FTXS25EVMA
Cooling
Heating
Cooling
Heating
Rated Capacity
3.5kW Class
2.5kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
8.9 (314)
9.7 (342)
8.7 (307)
9.4 (332)
M
6.9 (242)
7.9 (277)
6.7 (237)
7.6 (268)
L
4.8 (169)
6.0 (212)
4.7 (166)
5.8 (205)
SL
4.0 (141)
5.2 (184)
3.9 (138)
5.0 (177)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
40
Speed
Steps
5 Steps, Silent, Auto
5 Steps, Silent, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.19-0.18-0.17 / 0.19-0.18
0.19-0.18-0.17 / 0.19-0.18
0.17-0.16-0.15 / 0.17-0.16
0.17-0.16-0.15 / 0.17-0.16
Power Consumption (Rated)
W
40-40-40 / 40-40
40-40-40 / 40-40
35
35
Power Factor
%
95.7-96.6-98.0 / 95.7-96.6
95.7-96.6-98.0 / 95.7-96.6
93.6-95.1-97.2 / 93.6-95.1
93.6-95.1-97.2 / 93.6-95.1
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
283×800×195
283×800×195
Packaged Dimensions (H×W×D)
mm
265×855×340
265×855×340
Weight
kg
9
9
Gross Weight
kg
12
12
Operation
Sound
H/M/L/SL
dBA
38/26/23
38/29/26
37/31/25/22
37/33/28/25
Sound Power
H
dBA
—
—
—
—
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D049292
3D054406
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for FTKS50BVMB
Page 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Page 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Page 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Page 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Page 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Page 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Page 452: ...SiEN18 622 vi Index ...