![Daikin FTKS50BVMB Service Manual Download Page 44](http://html1.mh-extra.com/html/daikin/ftks50bvmb/ftks50bvmb_service-manual_501473044.webp)
SiEN18-622
Specifications
Specifications
31
Ceiling Mounted Cassette Type
50Hz 230V
H
( ) : dimension including control box
Model
FFQ25B8V1B
FFQ35B8V1B
Rated Capacity
2.5kW Class
3.5kW Class
Decoration
Panel
Color
White
White
Dimensions (H×W×D)
55×700×700
55×700×700
Air Flow Rates
m³/min
(cfm)
H
9.0 (318)
10.0 (353)
M
—
—
L
6.5 (230)
6.5 (230)
SL
—
—
Fan
Type
Turbo Fan
Turbo Fan
Motor Output
W
55
55
Speed
Steps
2 Steps
2 Steps
Air Direction Control
Horizontal, Downward
Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.37
0.40
Power Consumption (Rated)
W
73
84
Power Factor
%
85.8
91.3
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
H
mm
260 (286)×575×575
260 (286)×575×575
Packaged Dimensions (H×W×D)
mm
370×687×674
370×687×674
Weight
kg
17.5
17.5
Gross Weight
kg
21
21
Operation
Sound
H/L
dBA
29.5/24.5
32.0/25.0
Sound Power
H
dBA
46.5
49.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
VP20 (O.D.
φ
26 / I.D.
φ
20)
VP20 (O.D.
φ
26 / I.D.
φ
20)
Drawing No.
3D040444A
3D040442A
Model
FFQ50B8V1B
FFQ60B8V1B
Rated Capacity
5.0kW Class
6.0kW Class
Decoration
Panel
Color
White
White
Dimensions (H×W×D)
55×700×700
55×700×700
Air Flow Rates
m³/min
(cfm)
H
12.0 (424)
15.0 (530)
M
—
—
L
8.0 (283)
10.0 (353)
SL
—
—
Fan
Type
Turbo Fan
Turbo Fan
Motor Output
W
55
55
Speed
Steps
2 Steps
2 Steps
Air Direction Control
Horizontal, Downward
Horizontal, Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.49
0.61
Power Consumption (Rated)
W
97
120
Power Factor
%
86.1
85.5
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
H
mm
260 (286)×575×575
260 (286)×575×575
Packaged Dimensions (H×W×D)
mm
370×687×674
370×687×674
Weight
kg
17.5
17.5
Gross Weight
kg
21
21
Operation
Sound
H/L
dBA
36/27
41/32
Sound Power
H
dBA
53
58
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
VP20 (O.D.
φ
26 / I.D.
φ
20)
VP20 (O.D.
φ
26 / I.D.
φ
20)
Drawing No.
3D040437
3D040431
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for FTKS50BVMB
Page 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Page 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Page 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Page 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Page 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Page 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Page 452: ...SiEN18 622 vi Index ...