SiEN18-622
Specifications
Specifications
27
Duct Connected Type
50Hz 230V
Note:
The operating sound is based on the rear side suction inlet and the external static pressure 40 Pa.
Operating sound for under side suction inlet: [operating sound for rear side suction inlet]+5 dB.
However, when installation to which the external static pressure becomes low is carried out,
5 dB or more may go up.
Model
FDKS25CAVMB
FDKS35CAVMB
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
—
—
Air Flow Rates
m³/min
(cfm)
H
9.5 (335)
10.0 (353)
M
8.8 (311)
9.3 (328)
L
8.0 (282)
8.5 (300)
SL
6.7 (237)
7.0 (247)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
62
62
Speed
Steps
5 Steps, Silent, Auto
5 Steps, Silent, Auto
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.47
0.47
Power Consumption (Rated)
W
100
100
Power Factor
%
92.5
92.5
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
200×900×620
200×900×620
Packaged Dimensions (H×W×D)
mm
266×1,106×751
266×1,106×751
Weight
kg
25
25
Gross Weight
kg
31
31
Operation
Sound
H/M/L/SL
dBA
35/33/31/29
35/33/31/29
External Static Pressure
Pa
40
40
Moisture Removal
L/h
1.2
1.9
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
VP20 (O.D.
φ
26 / I.D.
φ
20)
VP20 (O.D.
φ
26 / I.D.
φ
20)
Drawing No.
3D048947C
3D048948C
Model
FDKS50CVMB
FDKS60CVMB
Rated Capacity
5.0kW Class
6.0kW Class
Front Panel Color
—
—
Air Flow Rates
m³/min
(cfm)
H
12.0 (424)
16.0 (565)
M
11.0 (388)
14.8 (523)
L
10.0 (353)
13.5 (477)
SL
8.4 (297)
11.2 (395)
Fan
Type
Sirocco Fan
Sirocco Fan
Motor Output
W
130
130
Speed
Steps
5 Steps, Silent, Auto
5 Steps, Silent, Auto
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.64
0.74
Power Consumption (Rated)
W
140
160
Power Factor
%
95.1
94.0
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
200×900×620
200×1,100×620
Packaged Dimensions (H×W×D)
mm
266×1,106×751
266×1,306×751
Weight
kg
27
30
Gross Weight
kg
34
37
Operation
Sound
H/M/L/SL
dBA
37/35/33/31
38/36/34/32
External Static Pressure
Pa
40
40
Moisture Removal
L/h
2.9
3.9
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
VP20 (O.D.
φ
26 / I.D.
φ
20)
VP20 (O.D.
φ
26 / I.D.
φ
20)
Drawing No.
3D052134A
3D052135
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for FTKS50BVMB
Page 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Page 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Page 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Page 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Page 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Page 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Page 452: ...SiEN18 622 vi Index ...