SiEN18-622
Indoor Unit (RA Models)
Function
125
7.7
ECONO Mode
Outline
20-35 Class
The "ECONO mode" reduces the maximum operating current and power consumption by
approx. 30% during start up etc..
This mode is particularly convenient for energy-saving-oriented users. It is also a major bonus
for those whose breaker capacities do not allow the use of multiple electrical devices and air
conditioners.
It is easily activated from the infrared remote control by pushing the ECONO button.
When this function is ON, the maximum capacity is also down. (Approx. 20%)
This function can only be set when the unit is running. Pressing the operation stop button
causes the settings to be canceled.
This function and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
Details
ECONO mode can be activated while the unit is running. The remote control can send the
ECONO command when the unit is in COOL, HEAT, DRY, or AUTO operation.
When the ECONO command is valid, the upper limit of frequency is restricted.
7.8
MOLD PROOF Operation
20-35 Class
MOLD PROOF operation is a function which reduces the spread of mold by using Fan mode to
lower the humidity inside the indoor unit.
Outline
MOLD PROOF operation starts when the following conditions are met.
1. MOLD PROOF is set on the remote control.
2. Cooling or dry operation stops.
MOLD PROOF operation will operate for approximately one hour after dry or cooling mode
is turned off.
The indoor fan rotates at 550 rpm.
Note:
1. This function is not designed to remove existing dust or mold.
2. MOLD PROOF operation is not available when the unit is turned off using the OFF TIMER.
Econo Mode
(R4607)
Power
con
su
mption
a
nd c
u
rrent
Norm
a
l
Time
Approx.
3
0%
Summary of Contents for FTKS50BVMB
Page 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Page 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Page 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Page 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Page 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Page 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Page 452: ...SiEN18 622 vi Index ...