Last Hop SPT
Switchover
This field is used by the last hop router to decide whether to receive multicast data from the
shared tree or switch over to the shortest path tree. When the switchover mode is set to
never, the last hope router will always receive multicast data from the shared tree. When the
mode is set to immediately, the last hop router will always receive data from the shortest path
tree.
Register Probe
Time (1-127)
This command is used to set a time to send a probe message from the DR to the RP before
the Register Suppression time expires. If a Register Stop message is received by the DR, the
Register Suppression Time will be restarted. If no Register Stop message is received within
the probe time, Register Packets will be resent to the RP. The user may configure a time
between
1
and
127
seconds with a default setting of
5
seconds.
Register
Suppression Time
(3-255)
This field is to be configured for the first hop router from the source. After this router sends
out a Register message to the RP, and the RP replies with a Register stop message, it will
wait for the time configured here to send out another register message to the RP. The user
may set a time between
3
and
255
with a default setting of
60
seconds.
Click
Apply
to implement changes made.
NOTE:
The Probe time value must be less than half of the Register
Suppression Time value. If not, the administrator will be presented with an
error message after clicking
Apply
.
PIM Interface Settings
This window is used to configure the settings for the PIM Protocol per IP interface.
To view this window, click
L3 Features > IP Multicast Routing Protocol > PIM > PIM Interface Settings
, as shown below:
Figure 4- 125. PIM Interface Settings window
To configure an IP interface for PIM, click its corresponding
Modify
button, which will lead you to the following window:
Figure 4- 126. PIM Interface Settings – Edit window
The following fields can be set:
267