xStack
®
DGS-3600 Series Layer 3 Managed Gigabit Ethernet Switch
DULD Settings
The Switch features a D-Link Unidirectional Link Detection (DULD) module. The unidirectional link detection provides a
mechanism that can be used to detect unidirectional link for Ethernet switches whose PHYs do not support unidirectional OAM
operation. This function is established based on OAM, so OAM should be enabled before starting detection.
To view this window, click
L2 Features > DULD Settings
, as shown below:
Figure 3- 81. DULD Settings window
The following fields can be set:
Parameter Description
Unit
Select the unit to configure.
From/To
Select a range of ports.
Admin State
Enable or disable the administration state. This indicates these ports unidirectional link
detection status. The default state is
Disabled
.
Mode
Toggle between
Shutdown
and
Normal
. When
Shutdown
is selected, if any unidirectional link
is detected, this feature will disable the port and log an event. When
Normal
is selected, this
feature will only log an event when a unidirectional link is detected.
Discovery Time (5-
65535 sec)
Enter the port neighbor discovery time between
5
and
65535
seconds. If the discovery is timed
out, the unidirectional link detection will start. The default discovery time is
5
seconds
Click
Apply
to create a new entry.
165