117
4.
Click
Next
to take the second calibration reading.
If the new calibration offsets are too large (> 0.5 degrees) for your AMS to operate reliably, a dialog
displays telling you to contact customer support at CyberOptics.
If the new calibration offsets are within the allowed limits, the wizard displays the
Step 4 of 4 Finish Calibration dialog, as shown above.
Click
Save
to save the new calibration values. That completes the zero-point calibration.