Temporarily Changing the Go/No-Go Tolerance
The Go/No-Go tolerance in effect at the time a log file entry is made is recorded in the log file as part of the log
entry. That value is used when you first display an entry from the log file. You can temporarily change the Go/No-
Go tolerance for the entry you are currently viewing. However, as soon as you select a new entry from the log file,
the Go/No-Go tolerance displayed reverts to that of the log file entry.
To temporarily change the Go/No-Go tolerance:
1)
Choose the menu item
Settings > Set Go/No-Go Tolerance
. The Set Go/No-Go Tolerance dialog is displayed,
as shown below.
2)
Specify the
New Go/No-Go tolerance
and click
OK
.
You can set the tolerance to any value in the range 0.05 to 3.8 degrees. However, if you are using a reference plane
(see “
), the maximum value is less than 3.8 degrees. You can
’t set a
tolerance that would extend the Go/No-Go circle beyond the edge of the left bubble display area. If you try to set a
value that is too large, MultiReview prompts you to enter a value that is within the correct range.