___________________________________________________
CXR Larus 80-100-400 Issue 2 July 2006 page
3-1
3 Specifications
_
__________________________________________________________________
3.1 General
3.101
The electrical, physical, and environmental specifications of the StarClock 200E
system are listed in the following paragraphs.
3.2 StarClock 200E Mounting Elements
3.21 Mounting
Shelf
3.211 Shelf
Power:
-48 Vdc nominal; current drain (fully loaded):
Stratum 3E/LNC
Stratum 2/TNC
Stratum 1/PRC
Cold start
2.28 amps
3.80 amps
4.00 amps
After warmup
1.83 amps
2.20 amps
2.30 amps
Expansion shelf only 0.90 amps
0.90 amps
0.90 amps
3.212 Approximate Power Consumption (fully loaded):
Initial
(cold)
Steady-state
Stratum 1/PRC
187 watts
110 watts (after 15 minutes)
Stratum 2/TNC
182 watts
105 watts (after 15 minutes)
Stratum 3E/LNC
110 watts
88 watts (after 5 minutes)
Expansion shelf only
25 watts
25 watts
3.213 System Supply Voltage:
-42 Vdc to -57 Vdc
3.214 Card Fuses (Type GMT):
54511/54512, 54541/54542, 54550
0.75 amp
All
others
2.00
amps
3.214 Recommended feeder fuses:
Master
shelf
7.5
amps
x2
Expansion
shelf
5.0
amps
x2