CXR Larus 80-100-400
Issue 1, July 2006
____________________________________________________________
_____________________________________________
page
4-5
described in Volume 3, the TL1/ITL1 User Manual, and Volume 4, the Menu User
Manual. However, the thresholds are initially set to industry standards, so this should be
considered before any changes are made.
4.25
Monitoring of Card Outputs
4.2510 Input cards, track and hold cards, and most output driver cards have monitoring
jacks intended for use with a standard test set with a monitor input (100 ohms
for DS1 and EIA RS-422, 130 ohms for CC, 120 ohms for E1; 20 dB standard
level). The signals available are:
1. 54511/54512/5413
Input
Recovered
DS1/E1/2048
KHz/CC/5
MHz/10 MHz A or B input reference
(depending on the slot)
2.
54522, 54523 Track and Hold
Framed all ones, if so configured, at
the clock output frequency
3.
54591 GPS Track and Hold
Framed all ones, if so configured, at
the clock output frequency
4.
54593 GPS Track and Hold
Framed all ones, if so configured, at
the clock output frequency
5. 54571
T1
Output
Framed
all
ones,
monitoring output #1
6. 54572
CC
Output
Composite
clock,
monitoring output #1
7. 54573
E1
Output
Framed
all
ones,
monitoring output #1
8.
54574 2.048 MHz Output
2.048 MHz square wave,
monitoring output #1
9.
54575-4 EIA RS-422 Output
1.544 MHz square wave,
monitoring output #1
10. 54575-5 EIA RS-422 Output
8 kHz square wave,
monitoring output #1
11. 54577 5/10 MHz Output
5/10 MHz,
monitoring output #1
4.3 StarClock 200E System Self Diagnostics
4.3010 The StarClock 200E system has a series of software and hardware self checks
as well as crosschecks between the microprocessor-controlled cards.
4.31
Model 54522, 54523, 54591, and 54593 Track and Hold Clock